Choose from 25 toxic sensors, 3 PID sensors with a 9. The Professional Plus is the world's most versatile water quality meter. Interchangeable cables and multiple accessories allow a single instrument to be quickly changed for use in the field as a handheld meter, for low flow sampling, or in the laboratory.
Did you know that Equipco also sells environmental field supplies? The Delay Time is the number of minutes after the pump is turned on before it actually starts sampling. The Run Time is the number of minutes the pump will sample before stopping and going into Run Delay mode. The Cycle Count variable defines the number of times that the Run Time intervals are executed. This completes the programming phase for this selected program number.
Once the pump is programmed it will default to the program number used for the last sampling run when the display is turned on [1]. To switch to another program number without making any changes, follow Steps 2A and 2B. The GilAir-3 and GilAir-5 air sampling pumps use rechargeable Nickel-Cadmium or Nickel-Metal-Hydride batteries that must be fully charged and properly maintained to achieve maximum pump run time.
The battery pack may be charged separately or while installed on the pump. Do not clean, open case, charge or replace battery while in an explosive atmosphere. Battery packs are charged through a built-in jack, on the side of the battery pack.
Note: The charging plug is polarized to prevent improper insertion. Do not short the battery terminals or the charging jack. Shorting will result in irreversible damage to the battery pack.
Nickel-Cadmium batteries will develop reduced capacity when they are not fully discharged and then fully recharged after sampling. Nickel-Cadmium and Nickel-Metal-Hydride batteries always have a small internal leakage current. If the battery pack has been removed from the charger for more than two days without use, it will require additional charging to restore it to full capacity. This process can be repeated two or three times without cause. Charger must be connected at AC mains supply Before being connected to battery or pump for charging.
A constant-rate charger that automatically shuts down when charging is complete. A dual rate charger that can be switched from constant-rate charge to trickle charge. A dual rate charger offering five-station timed constant-rate charging that automatically defaults to trickle charge. A five-station charger offering timed charging that defaults to a trickle charge in either a constant-rate charging mode or two diagnostic modes.
We recommend use of the Double Evaluation mode for maintenance only maximum once monthly for use with Nickel-Cadmium batteries. These modes offer no advantage with Nickel-Metal-Hydride batteries. The inlet filter should be changed after six months of regular use or whenever the outer portion of the filter becomes discolored.
The filter center retains its original color as a reference. Make certain the small center o-ring [5] is properly seated inside the pump. Part Number Description. Display Ranges Display Messages Dimensions GilAir Battery Pack GilAir 4. Battery Type Battery life estimates are based on proper battery maintenance.
Constant High Flow Range Flow Control Constant Flow Low Flow Multi-Flow Low Flow Install the Low Flow Module in a clean environment with the pump turned off. Make sure the o-ring seals [5] are properly seated. Make certain the mating boss clears the case opening prior to securing.
Do not overtighten. The front anti-tamper cover plate should be open and rotated. The pump should be off. Set up the calibration equipment as shown. Make certain that the sampling media [A] is properly installed as shown. The built-in rotameter does not indicate the flow rate through the sampling media.
The module is provided with an internal Luer taper for bag sampling. The unique feature of this system is that it will automatically shut the flow off when the bag has been filled. Install the Multi-Flow Module in a clean environment with the pump turned off. Make certain that the sampling media [A], [B], [C] or [D] is properly installed as shown. The built-in rotameter does not indicate the flow rate through the sampliing media.
Petersburg, Florida USA. The material within this manual is proprietary information and is to be used only to understand, operate, and service the instrument. Do not rub with dry cloth.
Substitution of components may impair intrinsic safety. Use only specified GilAir-5 battery packs. A flashing icon indicates battery voltage is below its nominal value.
Maximum indication is off. Pump should be off. PROG Figure 3. The filter center retains its original color as a reference. The pump should be off. Set up the calibration equipment as shown. Make certain that the sampling media [A] is properly installed as shown. The unique feature of this system is that it will automatically shut the flow off when the bag has been filled.
Make certain that the sampling media [A], [B], [C] or [D] is properly installed as shown. This manual is also suitable for: Gilair